Product Introduction
The 3W Twin Spot LED Emergency Light is a double-head emergency lighting fixture designed to provide backup illumination when normal power is interrupted.
The product uses two 3W LED light sources, providing a total LED source configuration of 2 × 3W. The two lamp heads can be adjusted to direct emergency illumination according to the building structure and installation requirements.
The current product specification lists an AC200–240V 50/60Hz input, a 3.6V 1800mAh rechargeable battery, approximately 24 hours charging time and 3 hours emergency operating time.
The fixture combines an injection-molded ABS housing with metal components and is designed for emergency lighting applications including stairs, corridors and general building areas.
Design
The emergency light uses a twin-spot design with two adjustable lamp heads.
Each head can be independently positioned to direct light toward different areas of a corridor, staircase or evacuation route.
The adjustable-head structure provides flexibility for installations where emergency illumination needs to cover more than one direction.
Key design elements include:
- Two adjustable LED lamp heads
- Compact emergency-lighting housing
- ABS plastic components
- Metal structural components
- LED status indicator
- Emergency test button
- Rechargeable battery system
- Ceiling or wall installation depending on the final mounting configuration
The adjustable lamp-head design is particularly suitable for stairways, corridors and areas where two-directional emergency illumination is required.
Main Features
2 × 3W LED Light Sources
The product uses two 3W LED light sources, providing a twin-head emergency lighting configuration.
3-Hour Emergency Operation
The current product specification states an emergency operating time of 3 hours after the battery has been charged.
Adjustable Twin Heads
The two lamp heads can be adjusted to suit the building structure and direct emergency illumination toward different areas.
Rechargeable Battery
The product uses a 3.6V 1800mAh rechargeable battery for emergency operation. The page also identifies battery protection against overcharging and over-discharging.
24-Hour Charging
The product specification lists a charging time of approximately 24 hours.
Emergency Test Button
A test button is provided to check the emergency lighting function during normal operation.
LED Battery Indicator
The integrated LED indicator helps monitor the battery operating status.
Long LED Service Life
The current product description states an LED operating lifespan of up to 100,000 hours.
CE / CB Approved Configuration
The product page identifies the DT Series emergency light as CE/CB approved. Certification should be confirmed for the exact production model and destination market before use in compliance documentation.
Application
The Twin Spot LED Emergency Light is suitable for emergency illumination in:
- Stairways
- Corridors
- Passageways
- Emergency routes
- Commercial buildings
- Office buildings
- Hotels
- Shopping malls
- Schools
- Hospitals
- Public buildings
- Industrial facilities
- Warehouses
- General building areas
The current product page specifically states use in general lighting, emergency lighting and stairs.
Size / Options
Current product information includes:
| Option |
Specification |
| Product Type |
Emergency Twin Spot Light |
| Model |
SK-00217 |
| LED Configuration |
2 × 3W LED |
| Input Voltage |
AC200–240V 50/60Hz |
| Battery |
3.6V 1800mAh |
| Battery Type |
Ni-Cd |
| Emergency Duration |
3 Hours |
| Charging Time |
24 Hours |
| Protection Rating |
IP30 |
| Housing |
Iron Metal + ABS Plastic |
| Lighting |
LED |
| Operation |
DC |
| Weight |
800g/pcs |
| Warranty |
2 Years |
Lighting Options
The product is designed for emergency illumination rather than exit signage.
The two adjustable LED heads can be positioned to provide directional illumination for:
- Stairways
- Corridors
- Passageways
- Emergency routes
- Building entrances
- Public areas
- Commercial spaces
For projects requiring directional exit identification rather than area illumination, USKYLED also offers dedicated LED emergency exit signs.
Installation
The emergency light should be installed in a location where backup illumination is required during power failure.
Typical installation areas include:
- Stairways
- Corridors
- Passageways
- Emergency routes
- Commercial buildings
- Hotels
- Schools
- Hospitals
- Shopping malls
- Public buildings
Recommended installation process:
- Determine the required emergency-lighting coverage.
- Select a suitable wall or ceiling mounting location.
- Position the two adjustable lamp heads toward the required illumination areas.
- Confirm the AC200–240V input specification of the final model.
- Connect the mains power according to the product wiring instructions.
- Allow the rechargeable battery to complete its charging cycle.
- Use the test button to verify emergency operation.
- Confirm that the two lamp heads provide suitable coverage.
- Check the battery indicator and emergency operating function.
Installation should comply with applicable local electrical, fire-safety and emergency-lighting regulations.
Project Applications
Commercial Building Projects
Suitable for:
- Office buildings
- Commercial complexes
- Retail facilities
- Business centers
- Public passageways
Hotel Projects
Suitable for:
- Hotel corridors
- Staircases
- Guest floors
- Emergency routes
- Public areas
School & Education Projects
Suitable for:
- School corridors
- Stairways
- Campus buildings
- Public passageways
- Emergency routes
Hospital Projects
Suitable for:
- Hospital corridors
- Staircases
- Public areas
- Emergency routes
- Service passageways
Shopping Mall Projects
Suitable for:
- Retail corridors
- Shopping areas
- Staircases
- Public passageways
- Emergency routes
Industrial & Warehouse Projects
Suitable for:
- Factories
- Warehouses
- Workshops
- Logistics facilities
- Industrial buildings
OEM/ODM
USKYLED supports OEM and ODM cooperation for rechargeable emergency lights and commercial emergency lighting projects.
Possible customization areas can include:
- Product housing
- Product dimensions
- LED power
- LED configuration
- Battery capacity
- Battery type
- Emergency operating time
- Input voltage
- Charging configuration
- Lamp-head design
- Lamp-head adjustment range
- Mounting method
- Product labeling
- Packaging
- Private-label production
- Project-specific configurations
For OEM/ODM projects, customers can provide the required voltage, emergency duration, battery specification, installation environment and estimated order quantity for technical confirmation.
MOQ: 1 pcs
Sample Order Lead Time: 3–7 Days
Mass Order Lead Time: 7–15 Days
CTA
Looking for rechargeable twin-spot emergency lights for stairs, corridors or commercial buildings?
Contact USKYLED for samples, wholesale pricing and OEM/ODM emergency lighting solutions.
MOQ: 1 pcs
Sample Lead Time: 3–7 Days
Mass Order Lead Time: 7–15 Days
DM us for product specifications, samples and bulk pricing.